| PRESS | English Description |
|---|---|
| RUN | Start the inverter |
| STOP/RESET | Stop operation / Fault reset |
| PRG | Enter or exit parameter setting mode |
| SHIFT | Shift cursor position / digit selection |
| ▲ (UP) | Increase setting value or parameter |
| ▼ (DOWN) | Decrease setting value or parameter |
| ENTER (OR SET) | Confirm input / Save parameter |


| LIGHT | English Description |
|---|---|
| RUN (绿色) | Inverter is running |
| STOP (红色) | Inverter stopped / Alarm active |
| Hz (黄灯) | Frequency mode indicator |
| A (黄灯) | Current monitoring mode |
| V (黄灯) | Voltage monitoring mode |
| ALM (红色) | Fault alarm |
| Parameter Address | Name | Grinding Head | Beam | Column (Dished Head) | Rotary Table | Roller Table |
|---|---|---|---|---|---|---|
| P0.00 | GP Type / GP | 1 | 1 | 1 | 1 | 1 |
| P0.01 | Control Mode | 1 | 1 | 1 | 1 | 1 |
| P0.02 | Run Command Channel Selection | 1 | 1 | 1 | 1 | 1 |
| P0.04 | Main Frequency Source Selection | 4 | 4 | 4 | 4 | 4 |
| P0.08 | Acceleration Time 1 | 10 | 2 | 2 | 10 | 10 |
| P0.09 | Deceleration Time 1 | 10 | 1 | 1 | 10 | 10 |
| P0.23 | Frequency Setting Memory at Stop | 1 | 1 | 1 | 1 | 1 |
| P6.02 | Relay Output Function (RA-RB-RC) | 1 | 1 | 1 | 1 | 1 |
| PP0.01 | Function Code (1 = Restore Factory Settings) |