Standard Model Zhongchen VFD Parameter Settings

Publish time:2025-04-15 20:59:36 Popularity:0 Source:未知来源

Zhongchen Z2000 Inverter Settings 

1. Digital Operator Instructions

2. Panel Diagram 

PRESS English Description
RUN Start the inverter
STOP/RESET Stop operation / Fault reset
PRG Enter or exit parameter setting mode
SHIFT Shift cursor position / digit selection
▲ (UP) Increase setting value or parameter
▼ (DOWN) Decrease setting value or parameter
ENTER (OR SET) Confirm input / Save parameter

3. Key Functions

 

4. Indicator Lights 

 

LIGHT English Description
RUN (绿色) Inverter is running
STOP (红色) Inverter stopped / Alarm active
Hz (黄灯) Frequency mode indicator
A (黄灯) Current monitoring mode
V (黄灯) Voltage monitoring mode
ALM (红色) Fault alarm

Common Inverter Parameters for Polishing Equipment 

Parameter Address  Name  Grinding Head  Beam  Column (Dished Head) Rotary Table  Roller Table
P0.00 GP Type / GP 1 1 1 1 1
P0.01 Control Mode 1 1 1 1 1
P0.02 Run Command Channel Selection  1 1 1 1 1
P0.04 Main Frequency Source Selection 4 4 4 4 4
P0.08 Acceleration Time 1  10 2 2 10 10
P0.09 Deceleration Time 1 10 1 1 10 10
P0.23 Frequency Setting Memory at Stop  1 1 1 1 1
P6.02 Relay Output Function (RA-RB-RC) 1 1 1 1 1
PP0.01 Function Code (1 = Restore Factory Settings)          